Numerical modelling of hip fracture patterns in human femur

Abal Arca, José; Marco, M.; Giner, E.; Caeiro-Rey, J. R.; Miguélez, M. H.; Larraínzar-Garijo, R.
Thumbnail
Estadísticas
Estadísticas
Ver Estadísticas de uso
Identificadores
Identificadores
URI: http://hdl.handle.net/20.500.11940/15498
PMID: 31046997
DOI: 10.1016/j.cmpb.2019.03.010
ISSN: 0169-2607
Registro completo
Servicios
Servicios
RISMendeleyLinksolver
Visualización o descarga de ficheros
Visualización o descarga de ficheros
Versión del editor (31.78Kb)
Fecha de publicación
2019
Título de revista
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE
Tipo de contenido
Artigo
Resumen
BACKGROUND AND OBJECTIVE: Hip fracture morphology is an important factor determining the ulterior surgical repair and treatment, because of the dependence of the treatment on fracture morphology. Although numerical modelling can be a valuable tool for fracture prediction, the simulation of femur fracture is not simple due to the complexity of bone architecture and the numerical techniques required for simulation of crack propagation. Numerical models assuming homogeneous fracture mechanical properties commonly fail in the prediction of fracture patterns. This paper focuses on the prediction of femur fracture based on the development of a finite element model able to simulate the generation of long crack paths. METHODS: The finite element model developed in this work demonstrates the capability of predicting fracture patterns under stance loading configuration, allowing the distinction between the main fracture paths: intracapsular and extracapsular fractures. It is worth noting the prediction of different fracture patterns for the same loading conditions, as observed during experimental tests. RESULTS AND CONCLUSIONS: The internal distribution of bone mineral density and femur geometry strongly influences the femur fracture morphology and fracture load. Experimental fracture paths have been analysed by means of micro-computed tomography allowing the comparison of predicted and experimental crack surfaces, confirming the good accuracy of the numerical model.

Navega

Todo RUNAColeccionesCentrosAutoresTítulosDeCSMeSHCIETipos de contenidosEsta colecciónCentrosAutoresTítulosDeCSMeSHCIETipos de contenidos

Estadísticas

Ver Estadísticas de uso

DE INTERÉS

Sobre Acceso AbiertoDerechos de autor
TwitterRSS
Xunta de Galicia
© Xunta de Galicia. Información mantida e publicada na internet pola Consellería de Sanidade o Servizo Galego de Saúde
Aviso legal | RSS
Galicia