Mostrar el registro sencillo del ítem

dc.contributor.authorGulías Soidán, Daniel 
dc.contributor.authorCruz Sánchez, Nilfa Milena
dc.contributor.authorFRAGA MANTEIGA, DANIEL 
dc.contributor.authorCao González, Ignacio 
dc.contributor.authorBalboa Barreiro, Vanesa
dc.contributor.authorGonzález Martín, Cristina
dc.date.accessioned2022-03-04T07:46:29Z
dc.date.available2022-03-04T07:46:29Z
dc.date.issued2020
dc.identifier.issn2075-4418
dc.identifier.otherhttps://www.ncbi.nlm.nih.gov/pubmed/33321706es
dc.identifier.urihttp://hdl.handle.net/20.500.11940/16160
dc.description.abstractBACKGROUND: The aim of this study was to evaluate the diagnostic capacity of Cone-Beam computed tomography (CT)-guided transthoracic percutaneous biopsies on lung lesions in our setting and to detect risk factors for possible complications. METHODS: Retrospective study of 98 biopsies in 94 patients, performed between May 2017 and January 2020. To obtain them, a 17G coaxial puncture system and a Siemens Artis Zee Floor vc21 archwire were used. Descriptive data of the patients, their position at the time of puncture, location and size of the lesions, number of cylinders extracted, and complications were recorded. Additionally, the fluoroscopy time used in each case, the doses/area and the estimated total doses received by the patients were recorded. RESULTS: Technical success was 96.8%. A total of 87 (92.5%) malignant lesions and 3 (3.1%) benign lesions were diagnosed. The sensitivity was 91.5% and the specificity was 100%. We registered three technical failures and three false negatives initially. Complications included 38 (38.8%) pneumothorax and 2 (2%) hemoptysis cases. Fluoroscopy time used in each case was 4.99 min and the product of the dose area is 11,722.4 microGy/m(2). CONCLUSION: The transthoracic biopsy performed with Cone-Beam CT is accurate and safe in expert hands for the diagnosis of lung lesions. Complications are rare and the radiation dose used was not excessive.es
dc.language.isoenes
dc.rightsAtribución 4.0 Internacional
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.titleCone-Beam CT-Guided Lung Biopsies: Results in 94 Patientsen
dc.typeJournal Articlees
dc.authorsophosGulias-Soidan, Daniel;Crus-Sanchez, Nilfa Milena;Fraga-Manteiga, Daniel;Cao-González, Juan Ignacio;Balboa-Barreiro, Vanesa;González-Martín, Cristina
dc.identifier.doi10.3390/diagnostics10121068
dc.identifier.pmid33321706
dc.identifier.sophos35581
dc.issue.number12es
dc.journal.titleDiagnostics (Basel)es
dc.organizationServizo Galego de Saúde::Estrutura de Xestión Integrada (EOXI)::EOXI de A Coruña - Complexo Hospitalario Universitario de A Coruña::Radiodiagnóstico
dc.organizationServizo Galego de Saúde::Estrutura de Xestión Integrada (EOXI)::Instituto de Investigación Biomédica da Coruña (INIBIC)
dc.relation.publisherversionhttps://mdpi-res.com/d://attachment/diagnostics/diagnostics-10-01068/article://deploy/diagnostics-10-01068.pdfes
dc.rights.accessRightsopenAccess
dc.subject.keywordCHUACes
dc.subject.keywordINIBIC
dc.typefidesArtículo Originales
dc.typesophosArtículo Originales
dc.volume.number10es


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Atribución 4.0 Internacional