Mostrar el registro sencillo del ítem
Evaluation of Change in Radiographic Fractal Dimension around Dental Implants Placed with Low-Speed Drilling and Standard Drilling Protocols
| dc.contributor.author | Soler-Alcaraz, S. | * |
| dc.contributor.author | Guerrero-Sánchez, Y. | * |
| dc.contributor.author | Pérez Sayáns, Mario | * |
| dc.contributor.author | Bernabeu-Mira, J.C. | * |
| dc.contributor.author | Peñarrocha-Oltra, D. | * |
| dc.contributor.author | Camacho-Alonso, F. | * |
| dc.date.accessioned | 2025-09-09T11:19:25Z | |
| dc.date.available | 2025-09-09T11:19:25Z | |
| dc.date.issued | 2023 | |
| dc.identifier.citation | Soler-Alcaraz S, Guerrero-Sánchez Y, Pérez-Sayáns M, Bernabeu-Mira JC, Peñarrocha-Oltra D, Camacho-Alonso F. Evaluation of Change in Radiographic Fractal Dimension around Dental Implants Placed with Low-Speed Drilling and Standard Drilling Protocols. Journal of Clinical Medicine. 2023;12(6). | |
| dc.identifier.issn | 2077-0383 | |
| dc.identifier.other | https://portalcientifico.sergas.gal//documentos/6444ede148c3090deaa261e5 | |
| dc.identifier.uri | http://hdl.handle.net/20.500.11940/21454 | |
| dc.description.abstract | Osseointegration is a process that depends on a multitude of factors, including the type of drilling, whether biological or conventional. Objective: Establish box-counting dimension values for radiological images in patients with implants placed with both drilling methods. Material and method: The sample included 129 implants corresponding to 50 patients. A double-blind study of data collection was carried out with the subsequent analysis of the fractal dimension as a comparative value of the state of the trabecular architecture. Results: We found no significant differences (p ? 0.05) between the two study groups comparing both drilling techniques. The values for the conventional drilling technique are 0.24 ± 0.07 and for biological drilling: 0.19 ± 0.11 with a p-value of 0.767. Conclusions: The drilling technique does not influence the success of the procedure and the osseointegration process. | |
| dc.description.sponsorship | This paper has been supported by Master en Cirugia e Implantologia Bucal, Hospital Morales Meseguer, Department of Oral Surgery, University of Murcia, Spain. | |
| dc.language | eng | |
| dc.rights | Attribution 4.0 International (CC BY 4.0) | * |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | * |
| dc.title | Evaluation of Change in Radiographic Fractal Dimension around Dental Implants Placed with Low-Speed Drilling and Standard Drilling Protocols | |
| dc.type | Artigo | |
| dc.authorsophos | Soler-Alcaraz, S.; Guerrero-Sánchez, Y.; Pérez-Sayáns, M.; Bernabeu-Mira, J.C.; Peñarrocha-Oltra, D.; Camacho-Alonso, F. | |
| dc.identifier.doi | 10.3390/jcm12062244 | |
| dc.identifier.sophos | 6444ede148c3090deaa261e5 | |
| dc.issue.number | 6 | |
| dc.journal.title | Journal of Clinical Medicine | * |
| dc.organization | Servizo Galego de Saúde::Áreas Sanitarias (A.S.) - Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS) | |
| dc.relation.projectID | Master en Cirugia e Implantologia Bucal, Hospital Morales Meseguer, Department of Oral Surgery, University of Murcia, Spain | |
| dc.relation.publisherversion | https://doi.org/10.3390/jcm12062244 | |
| dc.rights.accessRights | openAccess | * |
| dc.subject.keyword | AS Santiago | |
| dc.subject.keyword | IDIS | |
| dc.typefides | Artículo Científico (incluye Original, Original breve, Revisión Sistemática y Meta-análisis) | |
| dc.typesophos | Artículo Original | |
| dc.volume.number | 12 |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution 4.0 International (CC BY 4.0)