Mostrar el registro sencillo del ítem

dc.contributor.authorAguiar Fernández, Pablo
dc.contributor.authorCasarejos, E
dc.contributor.authorSilva Rodríguez, Jesús
dc.contributor.authorVilan, JA
dc.contributor.authorIglesias, A
dc.date.accessioned2017-06-07T06:55:54Z
dc.date.available2017-06-07T06:55:54Z
dc.date.issued2015
dc.identifier.issn0018-9499
dc.identifier.urihttp://hdl.handle.net/20.500.11940/684
dc.description.abstractEnvisaging the possibility of using large-area plastic scintillator slabs as robust detectors for high spatial resolution muon radiography, and prior to prototype development, we study expected basic performance by Monte Carlo simulation. We present preliminary results for a scalable square footprint detector unit of similar to 1 m(2), defining a representative simulation model volume of 50 cm x 50 cm, with reflective surfaces and a light readout by direct coupling of 4 small PMTs (in a square arrangement) at one face of the scintillator slab. Light detection efficiency is calculated for several light collection configurations, considering different values of surface roughness, reflectivity, optical coupling index and scintillator thickness. Values maximizing photon detection have been identified. The light response function of 2.5-3.5 cm diameter PMTs for the proposed configuration has been determined. A detector intrinsic spatial resolution of the order of 1 cm is estimated for muon interactions at the center region of the detector module, using a simple centroid positioning algorithm (Anger logic).
dc.language.isoeng
dc.rightsAttribution 4.0 International
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subject.meshCosmic rays
dc.subject.meshGATE
dc.subject.meshGeant4
dc.titleGeant4-GATE Simulation of a Large Plastic Scintillator for Muon Radiography
dc.typeArtigoes
dc.authorsophosAguiar, P
dc.authorsophosCasarejos, E
dc.authorsophosSilva-Rodriguez, J
dc.authorsophosVilan, JA
dc.authorsophosIglesias, A
dc.identifier.doi10.1109/TNS.2015.2431297
dc.identifier.isi356459900005
dc.identifier.sophos18737
dc.issue.number3
dc.journal.titleIEEE TRANSACTIONS ON NUCLEAR SCIENCE
dc.organizationServizo Galego de Saúde::Estrutura de Xestión Integrada (EOXI)::EOXI de Santiago::IDIS.- Instituto de investigaciones sanitarias de Santiago::Fundación Ramón Domínguez
dc.page.initial1233
dc.page.final1238
dc.rights.accessRightsopenAccess
dc.typesophosArtículo Original
dc.volume.number62


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution 4.0 International
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution 4.0 International